The Victron Energy Description:
The Cyrix-Li-Charge will connect a battery charger with 3 seconds delay:
The Cyrix-Li-Charge will disengage immediately whenever its control input becomes free floating, signalling cell over voltage or cell over temperature.
In general a cell over voltage alarm will reset shortly after charging has been stopped. The Cyrix will then reconnect the charger after a delay 3 seconds. After 2 attempts to reengage with 3 seconds delay, the delay increases to 10 minutes. Whenever battery voltage is less than 13,5 V (resp. 27 V or 54 V), the Cyrix will disengage with a delay of 1 hour. Note 1: In case of zero discharge current, or a small discharge current, the Cyrix will not disengage shortly after the charger has been switched off and/or disconnected, because battery voltage will remain higher than 13,5 V. Note 2: If, after the Cyrix has disengaged, the output of the battery charger immediately increases to 13,7 V or more, the Cyrix will reengage, with 3 seconds delay.
Specification | |
Brand | Victron Energy |
Part No | CYR010230430 |
Voltage (V) | 12v or 24v |
Continuous Current | 230A |
Current Consumption When Open | 4 mA |
LED Status Indication | Yes |
Control Cable Included (Length 1m) | Yes |
Weight (kg) | 0.3 |
Dimensions | L100 x W65 x H50mm |
IP Rating | IP54 |
Warranty | 5 Years |
Country of Manufacture | Malaysia |